3.38

Match? XXXXXXXXXXXXX

(bin)

Requests the bus pattern for match. Bus data and signal line patterns
are specified as true (

1

), false (

0

) or don't care (

X

). When displaying

hexadecimal data, changing the hexadecimal data byte automatically
changes the corresponding bus message. Use the [

→] and [←]

cursor keys to move between input fields. Use the [

↑] and [↓] cursor

keys to set values. Pressing [

↑] at the

NUL

bus message selects a

bus error (

ERROR

). Accept entry with [ENTER] and [EXIT] or

cancel with [ESC].

# of Matches? 00001

Requests the number of times the bus pattern should match before
starting the trigger delay. Number of matches can be from 1 to
65,535. Accept entry with [ENTER] and [EXIT] or cancel with
[ESC]

.

Trig Delay? 0000000

Requests the number of events to delay before starting the post
count. Trig delay can be from 1 to 9,999,999. Accept entry with
[ENTER]

and [EXIT] or cancel with [ESC].

Post Count? 00000

Requests the number of events in the trigger post count. Post
count

can be from 1 to 32,767. Accept entry with [ENTER] and

[EXIT]

or cancel with [ESC].

When Complete? Stop

Requests the recording action to be taken following the completion
of the post trigger count. The two choices are:

Stop

or

Step

.

Stop

allows the activity on the bus to continue at the selected handshake
speed.

Step

continues recording at single-step handshake rate (use

Advertising