Measurement Computing Analyzer488 User Manual

Page 78

Advertising
background image

Section 3

Front Panel Operation

3.32

Verifies that the record memory should be erased,

Yes

or

No

. Use

[

↑] and [↓] to select. Accept value with [ENTER] and [EXIT]

or cancel with [ESC]. A status message confirms that the record
memory is erased:

Record Memory Erased

[REC]

The Record key, [REC], is used to start or stop recording bus
events. When used to start recording, [REC] resets the recording
statistics seen using [STAT]. See also the descriptions of the
[VIEW]

, [FIND], and [PRINT] keys.

REC LED

The REC LED indicates the Analyzer488 is recording bus events.
Recording may be disabled by pressing [REC].

[ZERO]

The Zero command, [SHIFT][REC], resets the reference pointer
to location 0 without erasing the record memory. Further recording
will overwrite previous record memory locations. [ZERO] uses a
confirmation menu:

Reset Memory? Yes

Verifies that the record memory should be reset,

Yes

or

No

. Use

[

↑] and [↓] to select. Accept value with [ENTER] and [EXIT]

or cancel with [ESC]. A status message confirms that the record
memory is reset:

Record Memory Reset

[REL]

The Relative key, [REL], is used to toggle record memory location
addressing format between absolute memory addressing and relative
memory addressing. [REL] is valid only when viewing record
memory. To use relative addressing, set the reference pointer with
the Set Relative, [SET REL], command.

REL LED

The REL LED indicates the Analyzer488 is in relative addressing

Advertising