Zvei-3, Zvei-vdew – Wavecom W74PC V8.7.0 User Manual

Page 273

Advertising
background image

WAVECOM Decoder W74PC, W-PCI/e, W-CODE, W-CLOUD Manual V8.7.0

Transmission Modes

263

ZVEI-3

The entire call number is transmitted by consecutive tones in decade sequence. When two identical digits
are to be transmitted consecutively, then an eleventh frequency is used as a repetition identifier.

Parameter

Value

Frequency range

VHF/UHF

Operation modes

Analogue selcal

Receiver settings

FM, BW = 12 kHz

Modulation

FM, SUB Tone

Input format(s)

AF, IF

If more than two identical digits are to be transmitted, the repetition tone is appended to the digit tone
(e.g., 22222 is transmitted as f2 fw f2 fw f2, where f2 is the tone for "2" and fw is the repetition tone).

In most systems the accuracy of the single frequencies has to be within +1/-1.5% of the nominal value.

For ZVEI modes having nominal tone durations of 70 ms, the duration of a single tone may vary ± 15 ms.

Decoding the selective calls is started by clicking on a system. If transmission and system selection con-
form, the call sign is displayed on the monitor. In the Options menu a Time Stamp function can be ena-
bled to add date and time to each call.

Tone Allocation

Digit

Hz

Digit

Hz

0

2200

8

1830

1

970

9

2000

2

1060

A

886

3

1160

B

810

4

1270

C

740

5

1400

D

680

6

1530

E

2400

7

1670

Tone duration: 70 ms.

ZVEI-VDEW

The digital selective calling systems ZVEI and VDEW were defined for selective call and data transmission
in the non-public mobile land radio service. The ZVEI system adheres to the recommendation AK SRDS
87-3D, while the VDEW system was known as DIN45013 until 1992. The systems are identical on the
physical layer. Due to the special requirements of the VDEW some additional features where added to the
ZVEI system.

Parameter

Value

Frequency range

VHF/UHF

Operation modes

Digital Selcal

Modulation

FFSK

Symbol rate

1200 Bd

Center frequency

1500 Hz

Shift/Bandwidth

600 Hz