Wavecom W74PC V8.7.0 User Manual

Page 71

Advertising
background image

WAVECOM Decoder W74PC, W-PCI/e, W-CODE, W-CLOUD Manual V8.7.0

First start

61

Input Parameter

Value

Input Name

The name of the custom input

Device

Select Network in the list

Port number

Enter the a port number. The data source must be configured with the same port num-

ber

Format

Select VITA-49

Sampling Rate (Hz)

The sampling rate used by the data source

Channel

In the list box the channel(s) to be used are displayed: Mono, Left, Right, Left +

Right (PCM) and Left & Right (IQ).

VITA-49 Event Tag Size

The size (in bits) of the VITA-49 event tag. This parameter is ignored by W-CODE.

VITA-49 Channel Tag

Size

The size (in bits) of the VITA-49 channel tag. This parameter is ignored by W-CODE.

VITA-49 Item Packing

Field Size

The size of the item packing field. This field contains the event tag, the channel tag and

the data item, so the size must be at least (Event Tag Size) + (Channel Tag Size) +

(Data Item Size).

VITA-49 Data Item Size

The size of a data item. The data item contains the actual sample data.

VITA-49 Repeat Count

The repeat count. It is not supported by W-CODE and should be set to 1 as default.

VITA-49 Vector Size

The vector size. W-CODE does not support vectors, so this value should be set to 1 as

default.

VITA-49 Data Sample

Format

VITA-49 supports the following data sample formats:

Real: Real samples. Each sample consists of 1 data item.

Complex Cartesian: Each sample consists of 2 data items, which are the real

and imaginary parts of a complex number.

Complex Polar: Each sample consists of 2 data items, which are the vector

length and the angle of a complex number.

VITA-49 Data Sample

Format

The format of a data item. VITA-49 supports the following data item formats:

Signed Integer

Signed VRT (1-6 bits)

Unsigned Integer

Unsigned VRT (1-6 bits)

IEEE 754 Float (32 bits)

IEEE 754 Double (64 bits)

VRT is a special floating-poiint format of VITA-49, using 1 to 6 bits for the exponent and

the rest for the mantissa. Using VRT instead of one of the IEEE formats can reduce the

amount of TCP/IP data stream, and save streaming bandwidth.

VITA-49 Sample Com-

ponent Repeating

Sample Component Repeating. Not supported by W-CODE.

VITA-49 Link Efficient

Packing

This flag decides if data items should be packed to reduce the data size in some cases.

VITA-49 Stream ID

The VITA-49 stream id. Stream IDs are accepted but ignored. No filtering is done.

VITA-49 Radio Link

Packets

Enables the use of VITA-49.1 packets. Those packets, in addition to normal packets,

contain a unique identifier at the beginning and also support a CRC. This makes a VITA-

49 link much more robust.

Note: The VITA-49 parameters are default values. If a matching context packet is received that contains a
data stream format description, those values are overwritten by that context packet.

Advertising