WAVECOM Decoder W74PC, W-PCI/e, W-CODE, W-CLOUD Manual V8.7.0

Analysis Tools

89

 The name of each identified system is displayed in the output window. An identified system may

be immediately started by double-clicking the system in the output window - for instance double-
clicking BAUDOT ITA-2 in the figure above will interrupt FSK code checking and immediately start
BAUDOT ITA-2.

 The Hits-Checks will show you how often during checking a mode was successfully determined. If

multiple modes are listed this will indicate which mode should be tried.

 Some modes are very difficult to distinguish, especially when the system is in idle mode. The de-

coded text including text representations of the special characters IDLE ALFA, IDLE BETA and RQ
are important additional classification aids in determining the mode under examination.

 If a mode is uniquely identified, the software will switch to the identified mode and decoding is ini-

tiated with the measured values of mode, baud rate, shift, and center frequency.

 If two or more different systems are identified or if too many transmission errors occur, an auto-

matic switch to a mode will not take place.

Fast Scan/Full Scan

The Scan Mode can be selected by Options | Scan Mode… or by double-clicking the Scan Mode field in
the Status Bar.

The software proceeds to create a list of modes to check, which is displayed in the Code Check window.
The content of this list depends on the selection of the Fast Scan or Full Scan options.

 In Fast Scan mode, the list only contains the modes which are known to use the measured baud

rate, to reduce the evaluation time.

 In Full Scan every mode which is suitable for an FSK code check is listed, and all possible combi-

nations are checked.

FSK Code Check DIR

FSK code check is started in automatic mode by selecting the Analysis | Code Check button or from
VHF/UHF-DIR | Analysis | FSK Code Check. This function has a high degree of accuracy when deter-
mining baud rate, frequency shift and center frequency of HF FSK systems.

As an additional help FSK code check also offers an option to start the analysis manually after user entry
of baud rate, frequency shift and center frequency. To utilize this option the Auto button must be dese-
lected. The software will then start data acquisition using the pre-selected parameters. If a pre-selected
parameter has been changed data acquisition is atomatically restarted.

The selection of baud rate, frequency shift or center frequency is done by clicking on the status bar fields
or using the Demodulator menu.

If the FSK code check cannot identify a mode, the code check should be repeated. Data acquisition is con-
tinuously performed as a background task. Heavy fading or other disturbances during data acquisition
may prevent the identification of a mode.

You can also restart data acquisition by pressing the Resync button.

Because this kind of signal is not continuous, there is a need for a Noise Gate. The status of the noise
gate is displayed in the status bar; it examines the input signal and tries to determine if a valid signal is
available which can be processed, or if the input consists only of noise.