Example

Report DS1 facility operational parameters for NTT1-3.

REPT-OPSTAT-T1:TAMPA:NTT1-1;

TAMPA 01-11-24 12:30:43
M 42 COMPLD
/* REPT-OPSTAT-T1:TAMPA:NTT1-1:42 */
"NTT1-3:INCELLS,35500"
"NTT1-3:OUTCELLS,23300"
;

Related Commands

None

Table 4-9.

REPT-OPSTAT-T1 Response Parameters

Parameter Explanation

tid Target

NE

identification

yy-mm-dd

Year, month, and day

hh:mm:ss

Hour, minute, and second

M

Message generated in response to an input command

c

If provided, ctag; otherwise 0

COMPLD Completed

DENY

Input command is denied

/* */

Enclosed are human readable comments – unspecified format

errcde Error

code

(see

Appendix A,

Error Codes

)

aid_ds1

As described for command parameters (see

Table 4-8, REPT-OPSTAT-

T1 Command Parameters

).

op_ds1

DS1 operational parameter. Values are:

INCELLS: Rolling count of cells received on this facility.

OUTCELLS: Rolling count of cells transmitted on this facility and
discarded for any reason.

INCELLSUKN: Rolling count of cells received on this facility and
discarded during header validation with unrecognized VPI/VCI values.

OCD: Rolling count of Out of Cell Delineation events on this facility.

STATUSCD: Current status of cell delineation state. Values are:

– Normal: No failure condition

– LOCD: Loss Of Cell Delineation

value

Value of parameter specified by op_ds1.