10. Fault Commands

4200-A2-GB20-00

August 2002

10-7

ntfncde

As described for command parameters (see

Table 10-3,

RTRV-ALM-ALL Command Parameters

), except that ALL is not used.

cond

Condition. Valid values are:

ACTLPBK: Facility placed in loopback.

AIS: Alarm Indication Signal

EQPT: Equipment failed self-test

FACTERM: Modem could not initialize

FANALAM-1: Alarm for Fan 1

FANALAM-2: Alarm for Fan 2

LCD: Loss of ATM cell delineation

LCD-F: Loss of cell delineation (fast)

LOF: Loss of Frame

LOL: Loss of Link

LOS: Loss of Signal/clock

LPR: Loss of Power

LORATE: Line rate is below planned rate (Loss of Signal Quality)

PROGVER: Failed to load or find requested software

RAI: Remote Alarm Indication

RMTDLFAIL: Failed to download software

SWROLLBACK: Software version rolled back

serveff

As described for command parameters (see

Table 10-3,

RTRV-ALM-ALL Command Parameters

), except that ALL is not used.

[locn]

As described for command parameters (see

Table 10-3,

RTRV-ALM-ALL Command Parameters

).

[dirn]

As described for command parameters (see

Table 10-3,

RTRV-ALM-ALL Command Parameters

).

[cond_descr]

Description of alarm condition

Table 10-4.