Init-log, Response format – Paradyne 4200 User Manual

Page 234

Advertising
background image

11. Log Commands

11-2

August 2002

4200-A2-GB20-00

INIT-LOG

The INIT-LOG command initializes selected logs.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response will be sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* INIT-LOG:[tid]:[logid]:[ctag]::lognm */

;

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY
/* INIT-LOG:[tid]:[logid]:[ctag]::lognm */
errcde
;

Table 11-1.

INIT-LOG Command Parameters

INIT-LOG:[tid]:[logid]:[ctag]::lognm;

RESTRICTIONS: All parameters in this command are position-defined.

[tid]

The identification of the target NE. TID is optional and has a default
value of null. The NE's SID code is the only other valid value.

logid

COM is the only allowed value other than NULL for the AID field.

[ctag]

The correlation tag that correlates an input command with its associated
output response(s). It is assigned by the originator of the command. The
value is limited to six characters, which may be an identifier or a decimal
numeral. It is optional with a default of 0.

lognm

Names of logs to be initialized. Valid values are:

UNKCELL

[aid_atmport]: Unknown cell log for the ATM interface (see

ED-ATMPORT).

SYSTEM: System log containing records of all significant system events
(alarms, events, database chages, ftp file transfer status, and security
messages).

ALL: All logs.

Advertising