Rept alm adsl – Paradyne 4200 User Manual

Page 64

Advertising
background image

3. ADSL Facility Commands

3-28

August 2002

4200-A2-GB20-00

REPT ALM ADSL

The REPT ALM ADSL message reports current alarms associated with an ADSL
facility on an LT.

Table 3-23. REPT ALM ADSL Message Parameters (1 of 2)

almcode atag REPT ALM ADSL aid_adsl:ntfcde,cond_adsl,
srveff,[ocrdat],[ocrtm],[locn], [dirn];[cond_descr];

almcde

Alarm code. Identifies the severity of the alarm. Values are:

*C: Critical alarm

**: Major alarm

*^: Minor alarm

A^: Automatic message (typically reports a cleared alarm)

atag

Automatic tag indicating the numerical sequence of messages reported.

aid_adsl

Access identifier for the ADSL line(s). Enter in the following format,
replacing lower-case parameters with the values given:

ADSL-rack-shelf-slot-circuit

– rack: Rack Number (1)

– shelf: Shelf Number (1)

– slot: LT Slot Number (1)

– circuit: ADSL circuit on the LT (1

24)

Grouping and ranging are allowed.

ntfncde

Notification code. Valid values are:

CR: Critical alarm

MJ: Major alarm

MN: Minor alarm

CL: Cleared alarm

cond_adsl

ADSL condition. Valid values are:

FACTERM Modem could not initialize (Near End only)

LCD-F: Loss of Cell Delineation (fast) (Near End only)

LOF: Loss of Frame

LOL: Loss of Link

LORATE: Line rate is below planned rate (Loss of Signal Quality)

LOS: Loss of Signal (Near End only)

LPR: Loss of Power (Far End only)

[serveff]

Service effect. Valid values are:

SA: Service affecting

NSA: Not service affecting

ocrdat

Date of occurrence in the format mm-dd.

ocrtm

Time of occurrence in the format hh-mm.

Advertising