Rept alm eqpt – Paradyne 4200 User Manual

Page 150

Advertising
background image

7. Equipment Commands

7-4

August 2002

4200-A2-GB20-00

REPT ALM EQPT

The REPT ALM EQPT message reports current alarms from the NE.

Table 7-3.

REPT ALM EQPT Message Parameters

almcde atag REPT ALM EQPT aid_eqpts:ntfcde,cond_eqpt,
srveff,[ocrdat],[ocrtm]: [conddescr];

almcde

Alarm code. Identifies the severity of the alarm. Values are:

– *C: Critical alarm

– **: Major alarm

– *^: Minor alarm

– A^: Automatic message (typically reports a cleared alarm)

atag

Automatic tag. Indicates the numerical sequence of reported messages.

aid_eqpts

Access identifier for the equipment. Each AID format can be preceded
with AID=, but this is not required. Enter in the following format,
replacing lower-case parameters with the values given:

– LT-rack-shelf-slot: LT unit

– SHELF-rack-shelf: shelf

– rack: Rack Number (1)

– shelf: Shelf Number (1)

– slot: LT Slot Number (1)

[ntfncde]

Notification code. Valid values are:

– CR: Critical alarm

– MJ: Major alarm

– MN: Minor alarm

– CL: Cleared alarm

cond_eqpt

Equipment condition. Valid values are:

– EQPT: Equipment failed self-test

– FANALM-1: Fan alarm for fan 1

– FANALM-2: Fan alarm for fan 2

– PROGVER: Failed to load or find requested software

– RMTDLFAIL: Failed to download software

– SWROLLBACK: Software version rolled back

[serveff]

Service effect. Valid values are:

– SA: Service affecting

– NSA: Not service affecting

[ocrdat]

Date of alarm occurrence in the format mm-dd (month-day).

[ocrtm]

Time of alarm occurrence in the format hh-mm (hour-minute).

[conddescr]

Description of alarm condition (40 characters maximum).

Advertising