Example, Related command – Paradyne 4200 User Manual

Page 301

Advertising
background image

15. Test Commands

4200-A2-GB20-00

August 2002

15-3

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY
/* OPR-LPBK-T1:[tid]:aid_ds1:[ctag]::,,,[lpbktype] */
aid:ERRCDE=errcde
/* error description */
;

Example

Place NTT1 circuit 1 in payload loopback mode.

OPR-LPBK-T1:TAMPA:NTT1-1:40::,,,PAYLOAD;

TAMPA 01-11-24 12:30:43
M 40 COMPLD
/* OPR-LPBK-T1:TAMPA:NTT1-1:40::,,,PAYLOAD */
;

Related Command

RLS-LPBK-T1

on page 15-7

Table 15-2.

OPR-LPBK-T1 Response Parameters

Parameter Explanation

sid Source

NE

identification

yy-mm-dd

Year, month, and day

hh:mm:ss

Hour, minute, and second

M

Message generated in response to an input command

c

If provided, ctag; otherwise 0

COMPLD Completed

DENY

Input command is denied

/* */

Enclosed are human readable comments – unspecified format

errcde Error

code

(see

Appendix A,

Error Codes

)

Advertising