10. Fault Commands

4200-A2-GB20-00

August 2002

10-11

Example

Retrieve all service-affecting critical alarms for Network Termination Unit B.

RTRV-ALM-EQPT:TAMPA:NTB::CR,,SA;

TAMPA 02-06-27 03:38:43
M 42 COMPLD
/* RTRV-ALM-EQPT:TAMPA:NTB:42::CR,SA */
":NTB,EQPTS:CR,INT,SA,,,NEND,RCV,:Unknown error in
module"

;

Related Commands

None

cond_eqpt

Equipment condition. Valid values are:

EQPT: Equipment failed self-test

FANALM-1: Fan alarm for fan 1

FANALM-2: Fan alarm for fan 2

PROGVER: Failed to load or find requested software or configuration
file

RMTDLFAIL: Failed to download software or configuration

SWROLLBACK: Software version rolled back

serveff

As described for command parameters (see

Table 10-5,

RTRV-ALM-EQPT Command Parameters

), except that ALL is not used.

[cond_descr]

Description of alarm condition

Table 10-6.

RTRV-ALM-EQPT Response Parameters (2 of 2)

Parameter Explanation