Ed-user-secu, Response format – Paradyne 4200 User Manual

Page 246

Advertising
background image

12. Security Commands

12-8

August 2002

4200-A2-GB20-00

ED-USER-SECU

The ED-USER-SECU command edits the security levels and other
security-related parameters for a user.

NOTE:

You must enter a password to use the ED-USER-SECU command.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Table 12-7.

ED-USER-SECU Command Parameters

ED-USER-SECU:[tid]:uid:[ctag]::[newuid],[newpid],,[uap][:];

RESTRICTIONS: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID code
is the only other valid value.

uid

User Identification name (10 characters maximum). Input is
case-sensitive.

[ctag]

Correlation tag (6 characters maximum) that links an input command with
associated output responses. The default is 0.

[newuid]

New User Identification name (10 characters maximum). Input is
case-sensitive. The value must be unique within the NE. If not specified,
the value of this parameter remains unchanged.

[newpid]

New password (8

10 characters). The value must include at least one

digit, one letter, and one non-alphanumeric character. Input is
case-sensitive. If not specified, the value of this parameter remains
unchanged.

[uap]

User Access Privilege. Valid values are:

NULL: User has no access rights.

RTRV: Retrieve. Report and retrieve commands only (no configuring).

PROV: Configuring (provisioning). Report, retrieve, and configuring
commands allowed. No system administrator tasks including management
of the NE.

SUPER: Supervisor. All user functions allowed.

Advertising