Response format – Paradyne 4200 User Manual
Page 121
5. ATM Commands
4200-A2-GB20-00
August 2002
5-11
Response Format
If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:
IP c
After the above response, a new command input may be generated.
Normal Response:
sid yy-mm-dd hh:mm:ss
M c COMPLD
/*
ENT-VCL:[tid]:aid_vcl:[ctag]::[rcv_trafdsc],[xmt_trafdsc],
[rcv_trafdscnm],[xmt_trafdscnm] */
;
Error Response:
sid yy-mm-dd hh:mm:ss
M c DENY
/*
ENT-VCL:[tid]:aid_vcl:[ctag]::[rcv_trafdsc],[xmt_trafdsc],
[rcv_trafdscnm],[xmt_trafdscnm] */
aid:ERRCDE=errcde
/* error description */
;
Table 5-10. ENT-VCL Response Parameters
Parameter Explanation
tid Target
NE
identification
yy-mm-dd
Year, month, and day
hh:mm:ss
Hour, minute, and second
M
Message generated in response to an input command
c
If provided, ctag; otherwise 0
COMPLD Completed
DENY
Input command is denied
/* */
Enclosed are human readable comments – unspecified format
errcde Error
code