7. Equipment Commands

7-2

August 2002

4200-A2-GB20-00

ED-EQPT

The ED-EQPT command edits configuration data associated with equipment
supported by the system.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* ED-EQPT:[tid]:aid_eqpts:[ctag]::[eqpt_nblk]:[pst] */
;

Table 7-1.

ED-EQPT Command Parameters

ED-EQPT:[tid]:aid_eqpts:[ctag]::[eqpt_nblk]:[pst];

RESTRICTIONS: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.

aid_eqpts

Access identifier of an equipment unit. The value can be preceded with
AID=, but this is not required. Enter in one of the following formats,
replacing lower-case parameters with the values given:

LT-rack-shelf-slot
LTA (Line Termination Unit A)-rack-shelf-slot

– rack: Rack number (1)

– shelf: Shelf number (1)

– slot: LT slot number (1)

Grouping and ranging are allowed.

[ctag] Correlation

tag

(1

6 characters) that links an input command with

associated output responses. The default is 0.

[eqpt_nblk]

Named parameter block for equipment. Consists of the following
parameter name followed by an equal sign and a valid value:

– SWVER: Version of software that is configured (1

32 characters).

Input is case-sensitive. If not specified, the value of this
parameter remains unchanged. The system resets whenever the
software version is changed.

[pst]

Desired Primary State (LT or ACU only). Valid value is IS (In-Service). If
not specified, the value of this parameter remains unchanged.