12. Security Commands

12-6

August 2002

4200-A2-GB20-00

ED-PID

The ED-PID command edits a user’s own Private Identifier (password).

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/*
ED-PID:[tid]:uid:[ctag]::oldpid,newpid */
;

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY
/*
ED-PID:[tid]:uid:[ctag]::oldpid,newpid */
aid:ERRCDE=errcde
/* error description */
;

Table 12-5.

ED-PID Command Parameters

ED-PID:[tid]:uid:[ctag]::oldpid,newpid;

RESTRICTIONS: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.

uid

User Identification Name (10 characters maximum). Grouping is
allowed. Input is case-sensitive.

[ctag]

Correlation tag (6 characters maximum) that links an input command
with associated output responses.

oldpid

Old password.

newpid

New password (8

10 characters). Must include at least one digit, one

letter, and one nonalphanumeric character. Input is case-sensitive. The
newpid and oldpid values must be different.