Rept evt eqpt – Paradyne 4200 User Manual

Page 151

Advertising
background image

7. Equipment Commands

4200-A2-GB20-00

August 2002

7-5

REPT EVT EQPT

The REPT EVT EQPT message reports current equipment events from the NE.

Table 7-4.

REPT EVT EQPT Message Parameters

almcde atag REPT EVT EQPTaid_eqpt:cond_eqpt,[condeff],
[ocrdat],[ocrtm]:[conddescr];

almcde

Alarm code. Identifies the severity of the alarm. Values are:

– *C: Critical alarm

– **: Major alarm

– *^: Minor alarm

– A^: Automatic message (typically reports a cleared alarm)

atag

Automatic tag. Indicates the numerical sequence of reported messages.

aid_eqpt

Access identifier for the equipment. Each AID format can be preceded
with AID=, but this is not required. Enter in the following format,
replacing lower-case parameters with the values given:

– LT-rack-shelf-slot: LT unit

– SHELF-rack-shelf: shelf

– rack: Rack Number (1)

– shelf: Shelf Number (1)

– slot: LT Slot Number (1)

cond_eqpt

Equipment condition. Valid values are:

– EQPT: Equipment failed self-test

– FANALM-1: Fan alarm for fan 1

– FANALM-2: Fan alarm for fan 2

– PROGVER: Failed to load or find requested software or

configuration file

– RMTDLFAIL: Failed to download software or configuration

– SWROLLBACK: Software version rolled back

[condeff]

Effect of the event on the condition reported. Valid values are:

– SC: Standing condition raised

– CL: Standing condition cleared

[ocrdat]

Date of alarm occurrence in the format mm-dd (month-day).

[ocrtm]

Time of alarm occurrence in the format hh-mm (hour-minute).

[conddescr]

Description of alarm condition (40 characters maximum).