Example, Related commands – Paradyne 4200 User Manual

Page 261

Advertising
background image

13. Synchronization Commands

4200-A2-GB20-00

August 2002

13-7

Example

Retrieve the configuration of the reference source for synchronization of the NE
clock.

RTRV-SYNCN:TAMPA:CLKSRCNT:42;

TAMPA 01-12-20 11:20:34
M 42 COMPLD
/* RTRV-SYNCN:TAMPA:CLKSRCNT:42 */

CLKSRCNT::PRICREF=LOCAL;

Related Commands

ED-SYNCN

on page 13-2

Table 13-6.

RTRV-SYNCN Response Parameters

Parameter Explanation

tid

Target NE identification

yy-mm-dd

Year, month, and day

hh:mm:ss

Hour, minute, and second

M

Message generated in response to an input command

c

If provided, ctag; otherwise 0

COMPLD Completed

DENY

Input command is denied

/* */

Enclosed are human readable comments – unspecified format

errcde Error

code

(see

Appendix A,

Error Codes

)

aid_syncn

As described for command parameters

syncn_nblk

Named parameter block for SYNCN. The block consists of the
parameter PRICREF (primary local refernce source for synchronizing
the clock), followed by an equal sign (=) and one of the following values:

LOOP = Loop timing recovered form the network-side facility

LOCAL = Local oscillator on NT board