Set-ne-all, In chapter 14, System commands f – Paradyne 4200 User Manual

Page 293

Advertising
background image

14. System Commands

4200-A2-GB20-00

August 2002

14-31

SET-NE-ALL

The SET-NE-ALL command sets common configuration parameters associated
with the NE.

Table 14-25. SET-NE-ALL Command Parameters (1 of 2)

SET-NE-ALL:[tid]:[aid_com]:[ctag]:::ne_nblk;

RESTRICTION: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.

[aid_com]

Access Identifier for all common equipment. The value can be preceded
with AID=, but this is not required. The value is COM.

[ctag]

Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.

ne_nblk

Named parameter block for NE. The block consists of one or more of
the following parameters, each followed by an equal sign and a value. If
not specified, the values of these parameters remain unchanged.

BOOTPVCI : ATM VCI of the PVC over which the NE issues BOOTP
requests (32

1023) for ATM-1. The default value is 32.

BOOTPVPI: ATM VPI of the PVC over which the NE issues BOOTP
requests (0

15) for ATM-1. The default value is 0.

MEMALM: Used to clear alarm condition indicating loss or corruption of
persistent memory. The only valid value is CLEAR.

MEMDNLD: Determines whether an external download is persistent in
the database (typically used to restore the database from the previous
backup version). The only valid value is ENABLED.

DEFROUTER: IP address of default IP router. Values are:

– ddd.ddd.ddd.ddd: IP address (ddd = 1

255)

– NONE: No default IP router is used (default)

NETPOS: Position of the NE in the access subnetwork. Value is HUB
(NE is directly connected to the network).

SNTP: Use of Simple Network Time Protocol to maintain NE clock.
Values are:

– ENABLED: Use SNTP

– DISABLED: Use NE local time set by the command

SET-DAT

on

page 14-29.

TZOFFSET: Offset of local time zone from GMT/UTC, in minutes
(-780

780). The default is 0 minutes. Used by the system if SNTP is

enabled.

SNTPMODE: The SNTP mode. Valid values are:

– MULTI: Multicast (default)

– BROAD: Broadcast

– UNI: Unicast (to server at SNTPIPADDR)

Advertising