Example, Related command – Paradyne 4200 User Manual

Page 243

Advertising
background image

12. Security Commands

4200-A2-GB20-00

August 2002

12-5

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/*
ED-CID-SECU:[tid]:cid:[ctag]::chap,:[cid_nblk] */
;

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY
/*
ED-CID-SECU:[tid]:cid:[ctag]::chap:[cid_nblk] */
aid:ERRCDE=errcde
/* error description */
;

Example

Edit the local console interface to declare an intrusion alert after 3 invalid logon
attempts.

ED-CID-SECU:TAMPA:CRAFT:42::MXINV=3;

TAMPA 01-11-24 12:30:43
M 42 COMPLD
/* ED-CID-SECU:TAMPA:CRAFT:42::MXINV=3 */
;

Related Command

RTRV-CID-SECU

on page 12-12

Table 12-4.

ED-CID-SECU Response Parameters

Parameter Explanation

tid Target

NE

identification

yy-mm-dd

Year, month, and day

hh:mm:ss

Hour, minute, and second

M

Message generated in response to an input command

c

If provided, ctag; otherwise 0

COMPLD Completed

DENY

Input command is denied

/* */

Enclosed are human readable comments – unspecified format

errcde Error

code

(see

Appendix A,

Error Codes

)

Advertising