Example, Related commands – Paradyne 4200 User Manual

Page 72

Advertising
background image

3. ADSL Facility Commands

3-36

August 2002

4200-A2-GB20-00

Example

Retrieve ATU-R configuration data for rack 1, shelf 1, slot 1, circuit 9.

RTRV-ATUR:TAMPA:ATUR-1-1-1-9:42::::;

TAMPA 02-03-24 12:30:43
M 42 COMPLD
/* RTRV-ATUR:TAMPA:ATUR-1-1-1-9:42:::: */
ATUR-1-1-1-9,R1.01:01
;

Related Commands

None

Table 3-28. RTRV-ATUR Response Parameters

Parameter Explanation

tid Target

NE

identification

yy-mm-dd

Year, month, and day

hh:mm:ss

Hour, minute, and second

M

Message generated in response to an input command

c

If provided, ctag; otherwise 0

COMPLD Completed

DENY

Input command is denied

/* */

Enclosed are human readable comments – unspecified format

errcde Error

code

(see

Appendix A,

Error Codes

)

aid_atur

As described for command parameters (see

Table 3-27, RTRV-ATUR

Command Parameters

), except that ALL is not used

adsl_nblk

Named parameter block for ADSL line. The block consists the following
parameter and a valid value.

CURSWER: Installed version of software (1

32 characters). If

equipment is not installed or no software is available, no value is shown.

Advertising