Ed-syncn, Response format – Paradyne 4200 User Manual

Page 256

Advertising
background image

13. Synchronization Commands

13-2

August 2002

4200-A2-GB20-00

ED-SYNCN

The ED-SYNCN Command configures the reference source for synchronization of
the NE clock.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* ED-SYNCN:[tid]:[aid_syncn]:[ctag]:::[syncn_nblk] */
;

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY
/* ED-SYNCN:[tid]:[aid_syncn]:[ctag]:::[syncn_nblk] */
aid:ERRCDE=errcde
/* error description */
;

Table 13-1.

ED-SYNCN Command Parameters

ED-SYNCN:[tid]:[aid_syncn]:[ctag]:::[syncn_nblk];

Restrictions: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.

[aid_syncn]

AID of the NE clock. The value is CLKSRCNT.

[ctag]

Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.

syncn_nblk

Named parameter block for SYNCN. The block consists of one or more
of the following parameters, in any order separated by commas, each
followed by an equal sign and a valid value. If not specified, the value of
this parameter remains unchanged.

PRICREF: Primary reference source for synchronizing the clock. Valid
values are:

– LOOP: Loop timing recovered from network side facility

– LOCAL: Local oscillator on NT board

Advertising