background image

13. Synchronization Commands

4200-A2-GB20-00

August 2002

13-3

Example

Configure the NE clock to use the local oscillator as its primary reference source.

ED-SYNCN:TAMPA:CLKSRCNT:42:::PRICREF=LOCAL;

TAMPA 01-12-20 11:20:34
M 42 COMPLD
/* ED-SYNCN:TAMPA:CLKSRCNT:42:::PRICREF=LOCAL*/
;

Related Commands

RTRV-SYNCN

on page 13-6

Table 13-2.

ED-SYNCN Response Parameters

Parameter Explanation

tid

Target NE identification

yy-mm-dd

Year, month, and day

hh:mm:ss

Hour, minute, and second

M

Message generated in response to an input command

c

If provided, ctag; otherwise 0

COMPLD Completed

DENY

Input command is denied

/* */

Enclosed are human readable comments – unspecified format

errcde Error

code

(see

Appendix A,

Error Codes

)