4. DS1 Facility Commands

4-16

August 2002

4200-A2-GB20-00

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* RTRV-T1:[tid]:aid_ds1:[ctag]::::[pstf],[sstf] */
aid_ds1::ds1_nblk:state[,sst]
;

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY
/* RTRV-T1:[tid]:aid_ds1:[ctag]::::[pstf],[sstf] */
aid_ds1:ERRCDE=errcde
/* error description */
;

Table 4-13. RTRV-T1 Response Parameters (1 of 2)

Parameter Explanation

tid Target

NE

identification

yy-mm-dd

Year, month, and day

hh:mm:ss

Hour, minute, and second

M

Message generated in response to an input command

c

If provided, ctag; otherwise 0

COMPLD Completed

DENY

Input command is denied

/* */

Enclosed are human readable comments – unspecified format

aid_ds1

As described for command parameters

ds1_nblk

Named parameter block for DS1 facility. The block consists of one or
more of the following parameters, in any order separated by commas,
each followed by an equal sign and a valid value.

EQLZ: Line equalization (T1 short haul interfaces only). See

Table 4-4,

T1 Line Equalization Values

. Default is 0.

LBO: Line build-out in dB (T1 long haul interfaces only). Valid values are
0 (default), 7.5, 15, and 22.5.

LINETYPE: Type of line interface used. Valid values are:

– G703SHORT120: For E1 model. G.703 short-haul interface

(120 ohm connector).

– DSX1: For T1 model. T1 short-haul interface.

– G703LONG: For E1 model. G.703 long-haul interface (120 ohm

connector). Default for E1 models.

– T1: T1 power loop. For T1 model. T1 long-haul interface. Default

for T1 models.

– G703SHORT75: For E1 model. G.703 short-haul interface

(75 ohm connector).