Rtrv-atmport, Response format – Paradyne 4200 User Manual

Page 123

Advertising
background image

5. ATM Commands

4200-A2-GB20-00

August 2002

5-13

RTRV-ATMPORT

The RTRV-ATMPORT command retrieves configuration data associated with an
ATM port in the NE.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* RTRV-ATMPORT:[tid]:aid_atmport:[ctag]::::[pstf][sstf]
*/
;

Table 5-11. RTRV-ATMPORT Command Parameters

RTRV-ATMPORT:[tid]:aid_atmport:[ctag]::::[pstf],[sstf];

RESTRICTIONS: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.

aid_atmport

Access Identifier for an ATM port. The value can be preceded with
AID=, but this is not required. Grouping and ranging are allowed. Enter
any of in the following formats, replacing lower-case parameters with
the values given:

NTATM: ATM port in the NT

LTATM-1-1-slot-circuit: ATM port for an LT circuit

– slot: LT slot number (1)

– circuit: ADSL circuit on the LT (1

24)

[ctag]

Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.

pstf

Primary State Filter. Valid values are:

IS: In Service

OOS: Out Of Service

sstf

Secondary State Filter. The only valid value is LPBK (loopback).

Advertising