Error Response:
sid yy-mm-dd hh:mm:ss
M c DENY
/* ED-EQPT:[tid]:aid_eqpts:[ctag]::[eqpt_nblk]:[pst] */
aid:ERRCDE=errcde
/* error description */
;
Example
Edit ACU unit in rack 1, shelf 1 to be In-Service.
ED-EQPT:TAMPA:ACU-1-1:42::::IS;
TAMPA 01-11-24 12:30:43
M 42 COMPLD
/* ED-EQPT:TAMPA:ACU-1-1:42::::IS */
;
Related Commands
Table 7-2.
ED-EQPT Response Parameters
Parameter Explanation
tid Target
NE
identification
yy-mm-dd
Year, month, and day
hh:mm:ss
Hour, minute, and second
M
Message generated in response to an input command
c
If provided, ctag; otherwise 0
COMPLD Completed
DENY
Input command is denied
/* */
Enclosed are human readable comments – unspecified format
errcde Error
code