Example, Related commands – Paradyne 4200 User Manual

Page 149

Advertising
background image

7. Equipment Commands

4200-A2-GB20-00

August 2002

7-3

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY
/* ED-EQPT:[tid]:aid_eqpts:[ctag]::[eqpt_nblk]:[pst] */
aid:ERRCDE=errcde
/* error description */
;

Example

Edit ACU unit in rack 1, shelf 1 to be In-Service.

ED-EQPT:TAMPA:ACU-1-1:42::::IS;

TAMPA 01-11-24 12:30:43
M 42 COMPLD
/* ED-EQPT:TAMPA:ACU-1-1:42::::IS */
;

Related Commands

RTRV-EQPT

on page 7-6

Table 7-2.

ED-EQPT Response Parameters

Parameter Explanation

tid Target

NE

identification

yy-mm-dd

Year, month, and day

hh:mm:ss

Hour, minute, and second

M

Message generated in response to an input command

c

If provided, ctag; otherwise 0

COMPLD Completed

DENY

Input command is denied

/* */

Enclosed are human readable comments – unspecified format

errcde Error

code

(see

Appendix A,

Error Codes

)

Advertising