Response format, Example – Paradyne 4200 User Manual

Page 53

Advertising
background image

3. ADSL Facility Commands

4200-A2-GB20-00

August 2002

3-17

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* ED-PROFILE-ADSLDNALM:[tid]:adsl_profile_id:[ctag]:::
[adslprof_nblk] */
;

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY
/* ED-PROFILE-ADSLDNALM:[tid]:adsl_profile_id:[ctag]:::
[adslprof_nblk] */
errcde
;

Example

Edit profile 6 to have an Errored Seconds threshold of 2.

ED-PROFILE-ADSLDNALM:TAMPA:6:42:::ES-L=2;

TAMPA 02-07-24 12:30:43
M 42 COMPLD
/* ED-PROFILE-ADSLDNALM:TAMPA:6:42:::ES-L=2; */

;

Table 3-14. ED-PROFILE-ADSLDNALM Response Parameters

Parameter Explanation

tid Target

NE

identification

yy-mm-dd

Year, month, and day

hh:mm:ss

Hour, minute, and second

M

Message generated in response to an input command

c

If provided, ctag; otherwise 0

COMPLD Completed

DENY

Input command is denied

/* */

Enclosed are human readable comments – unspecified format

errcde Error

code

(see

Appendix A,

Error Codes

)

Advertising