Rtrv-pm-t1 – Paradyne 4200 User Manual

Page 104

Advertising
background image

4. DS1 Facility Commands

4-12

August 2002

4200-A2-GB20-00

RTRV-PM-T1

The RTRV-PM-T1 command retrieves DS1 performance monitoring data.

Table 4-10. RTRV-PM-T1 Command Parameters (1 of 2)

RTRV-PM-T1:[tid]:aid_ds1:[ctag]::[monds1],[monlev],[locn],,
[tmper],[mondat],[montm];

Restrictions: All parameters in this command are position-defined.

[tid]

The identification of the target NE. TID is optional and has a default
value of null. The NE's SID code is the only other valid value.

aid_ds1

Access identifier for the environment. Enter in the following format,
replacing lower-case parameters with the values given:

NTT1-circuit

– circuit: DS1 circuit on the NT (1)

[ctag]

The correlation tag that correlates an input command with its associated
output response(s). It is assigned by the originator of the command. The
value is limited to six characters, which may be an identifier or a decimal
numeral. It is optional with a default of 0.

[monds1]

Monitored parameter. Valid values are:

CV-L: Line code violations

ES-L: Line errored seconds

CV-P: Path coding violations

ES-P: Path errored seconds

ESB-P: Path errored seconds, type B (bursty errored seconds)

SES-P: Path severely errored seconds

UAS-P: Path unavailable seconds

SEFS-P: Path severely errored framing seconds

DHECV: Discarded cells due to HEC violation

Grouping is allowed. If no value is specified, ALL is assumed.

[monlev]

Threshold level. Valid values are:

lev-dirn

– lev: level (0

4294967295)

– dirn: direction. Values are UP and DN.

If no value is specified, 1-UP is assumed.

[locn]

Location of the facility. Valid values are:

NEND: Near end

FEND: Far end (not supported on G.703 interfaces)

If no value is specified, this parameter is not used for filtering
responses.

[tmper]

Time period. The only valid value is 15-MIN (15 minutes).

Advertising