Response format – Paradyne 4200 User Manual
Page 295
14. System Commands
4200-A2-GB20-00
August 2002
14-33
Response Format
If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response will be sent:
IP c
After the above response, a new command input may be generated.
Normal Response:
sid yy-mm-dd hh:mm:ss
M c COMPLD
/* SET-NE-ALL:[tid]:[aid_com]:[ctag]:::ne_nblk */
aid_com::ne_nblk
;
Error Response:
sid yy-mm-dd hh:mm:ss
M c DENY
/* SET-NE-ALL:[tid]:[aid_com]:[ctag]:::ne_nblk */
aid:ERRCDE=errcde
/* error description */
;
Table 14-26. SET-NE-ALL Response Parameters
Parameter Explanation
sid Source
NE
identification
yy-mm-dd
Year, month, and day
hh:mm:ss
Hour, minute, and second
M
Message generated in response to an input command
c
If provided, ctag; otherwise 0
COMPLD Completed
DENY
Input command is denied
/* */
Enclosed are human readable comments – unspecified format
errcde Error
code