Rd-syncn, Response format – Paradyne 4200 User Manual

Page 258

Advertising
background image

13. Synchronization Commands

13-4

August 2002

4200-A2-GB20-00

RD-SYNCN

The RD-SYNCN Command retrieves the current reference source for
synchronization of the NE clock.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* RD-SYNCN:[tid]:aid_syncn:[ctag][:] aid_syncn,cref */
;

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY
/* RD-SYNCN:[tid]:aid_syncn:[ctag][:] */
aid:ERRCDE=errcde
/* error description */
;

Table 13-3.

RD-SYNCN Command Parameters

RD-SYNCN:[tid]:[aid_syncn]:[ctag][:];

Restrictions: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.

[aid_syncn]

AID of the NE clock. The value is CLKSRCNT.

[ctag]

Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.

Advertising