Ml24xxa native commands gpib operation – Anritsu ML2430A User Manual

Page 155

Advertising
background image

Remarks:

This function is used to toggle a sensor’s range hold off or on, to set a spe-
cific range to be held, or to select AUTO ranging. RGH sent with only the
sensor parameter will toggle the sensor between holding the present oper-
ating range and AUTO. If RGH is sent with sensor and value parameters,
the sensor range mode will be set to the range value sent.

Query:

RGH? <s>

Returned

String:

RGH <s>,<val>

RSBAUD

RS232 Baud Rate

SYSTEM

Syntax:

RSBAUD <val>

val:

12,24,48,96,192 or 384 hundred bits per second

Remarks:

Sets the RS232 Baud rate for the rear panel serial port.

Query:

RSBAUD?

Returned

String:

RSBAUD <val>

RSMODE

RS232 Operating Mode

SYSTEM

Syntax:

RSMODE <s>

s:

EXTCOM
SRCSWP

Remarks:

EXTCOM = External communication. GPIB commands are sent and re-
ceived via an RS232 connection.
SRCSWP = Source sweep. Connected to a sweeper so updates to the
sweepers power of frequencies etc. are automatically updated on the
ML2430A Series also.

Query:

RSMODE?

Returned

String:

RSMODE <s>

SECURE

Secure system state

SYSTEM

Syntax:

SECURE <state>

state:

ON or OFF

6-68

ML2430A OM

ML24XXA NATIVE COMMANDS

GPIB OPERATION

Advertising