6.14

Model 644E-42/944E-42

Rev. 6/04

6.7.4

After Transmission Service or
Replacement

Refer to the ZF 4WG-92/98 TSC Repair Manual, JLG P/N

8990495 (ZF part number 5871.134.002) for information
on servicing the transmission after overhaul or repair. In
general:

1. Check the transmission oil level and add oil as

required.

2. Install a new transmission filter.

3. Check the torque on the drive shaft yoke capscrews.

4. Wear suitable eye protection. When an overhauled

or repaired transmission is installed, thoroughly
clean the oil cooler lines to and from the
transmission.

5. Drain and flush the entire system.

6. Disconnect and clean all transmission cooler hoses.

When possible, remove transmission lines from the
vehicle for cleaning.

7. Thoroughly clean transmission filter screens and

cases, and replace transmission filter elements.

8. Back flush the transmission oil cooler portion of the

radiator with oil and compressed air until all foreign
material is removed. Flushing in the direction of
normal oil flow does not adequately clean the cooler.
If needed, remove the radiator from the vehicle.

IMPORTANT: DO NOT use flushing compounds for
cleaning purposes.

9. Reassemble all components and fill the transmission

with clean, fresh Universal Tractor Fluid through the
dipstick tube opening (1). Remove the dipstick and
fill with approximately 15.9 qt (15 liters) of Universal
Tractor Fluid. Check the level by taking intermittent
dipstick readings as outlined in the appropriate
Owners/Operators Manual. DO NOT overfill.
Reinstall the dipstick when finished.

10. Run the engine for two minutes at idle (1,000-1,100

rpm) to help prime the torque converter and the
transmission oil lines.

11. Recheck the level of the fluid in the transmission with

the engine running at idle (1,000-1,100 rpm).

12. Add Universal Tractor Fluid as necessary to bring

the fluid level up until it reaches the FULL mark on
the dipstick. Recheck the oil level when it reaches
operating temperature 180-200° F (83-94° C).

13. Recheck all drain plugs, lines, connections, etc., for

leaks, and tighten where necessary.

CAUTION:

DO NOT exceed 165 psi

(39,6 bar) when back flushing the oil cooler.
Applying too much pressure may damage the
oil cooler/radiator.

MU1050