Engine Air-Intake Heater Indicator Troubleshooting (644E-42 Option, 944E-42 Standard)

Grid heater

OK.

Yes

No

0000000

RPM X 100

5

10

15

30

20

25

F

1/2

E

104

176

80

248

120

°C

°F

r/min

D

MU4390

Check for voltage at grid

heater element

Engine air-intake

heater indicator

stays ON

while operating.

Replace harness

If temperature is below

50° F (10° C), grid heater

post heat can be on up to

two (2) minutes.

Check for voltage at grid

heater relay coils.

If OK

Replace grid heater relays.

Does grid heater cycle ON/OFF?

If OK

Not

OK

Not

OK

If temperature is above

50° F (10° C):

Engine Air-Intake

Heater Indicator

Activate the ECM diagnostic system

and read the code as indicated by the

flashing lights on the indicator, located

on the left side of the dash between

the park brake switch and the

transmission disconnect switch.

Contact your local Cummins dealer

for an explanation of the code, refer to

the Cummins Engine Owners Manual

or call the Cummins Customer

Assistance Center at

1-800-343-7357.

944E-42

644E-42

Replace grid heater

control box.

Before troubleshooting any
electrical circuit, ALWAYS begin
by checking the following:

1. Fuses.

2. Battery for proper charge.

3. All connections relating to

circuit are clean and tight.

4. All grounding straps are intact

and securely fastened, refer to
Section 9.1.12, “General
Overview (Vehicle Ground
Strap Locations).”

5. Check dash panel bulbs for

proper function.