Section 9.12.2, “battery or, Batteries,” f, To section 9.12.2, “battery – Lull 944E-42 Service Manual User Manual

Page 681: Or batteries, 2 battery or batteries, Warning

Advertising
background image

9.171

Model 644E-42/944E-42

Rev. 6/04

Electrical System

6. Lower and lock engine cover. To release and lower

the engine cover (17) from the fully raised position,
lift up slightly on the cover and push the upper part
of the right gas shock (18) (orange tab) to the left.
Line up the upper part of the shock lock tube with the
lower part of the gas shock and pull the cover down
to the closed position.

9.12.2

Battery or Batteries

The standard vehicle has one battery. The vehicle with
cold start option has two batteries. In either case the
batteries are 12-volt, lead acid type, negative (-) ground,
maintenance-free batteries rated at 850 cold-cranking
amps. (Refer to appropriate Owners/Operators Manual
for general information.)

a. Battery Description

The battery supplies power to the starter and ignition
system to crank the engine, and it provides extra power
when the electrical load requirements of the vehicle
exceed the supply from the charging system in the event
of an alternator or charging-system failure. The battery
also acts as a voltage stabilizer in the electrical system,
smoothing out or reducing temporarily high voltage.

MU0650

11

12

13

16

15

14

4110390

1.

2.

OU0780

17

18

18

WARNING:

All lead acid batteries

generate hydrogen gas, which is highly
flammable. If ignited by a spark or flame, the
gas may explode violently, causing spraying of
acid, fragmentation of the battery, and possible
severe personal injuries. Wear safety glasses
when working near batteries. In case of
contact with acid, flush immediately with water.

Advertising
This manual is related to the following products: