I/O terminals

6.1

Digital terminals

110

Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Parameterisation dialog in the »Engineer«

Short overview of parameters for the digital terminals:

Button

Function
Indicates the polarity of the input is HIGH active.

The polarity can be changed from HIGH active to LOW active by clicking on this button.

Indicates that the polarity of the input is LOW active.

The polarity can be changed from LOW active to HIGH active by clicking on this button.

Open the parameterising dialog for assigning application inputs to the digital input.

Changing the terminal assignment with the »Engineer« ( 116)

Parameter

Info

Lenze setting

Value Unit

Digital inputs DI1 ... DI5

C114

DIx: Polarity

Bit coded

C443/1

DIx: Terminal level

-

C443/2

DIx: Output level (to the application)

-

Digital output DO1 / relay output

C118

DOx: Inversion

Bit coded

C444/1

DOx: Input level (from the application)

-

C444/2

DOx: Terminal level

-

Digital outputs - terminal configuration

C621/1

LS_DigitalOutput:bRelay

50: LA_nCtrl_bDriveFail

C621/2

LS_DigitalOutput:bOut1

51: LA_nCtrl_bDriveReady

Highlighted in grey = display parameter