C00868 | can output words, C00909 | speed limitation, C909/1 – Lenze 8400 BaseLine C User Manual

Page 295: C909/2, C909, Or out, C868/1, C868/2, C868/3, C868/4

Advertising
background image

10

Parameter reference

10.2

Parameter list | C00868

295

Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00868

C00909

Parameter | Name:

C00868 | CAN output words

Data type: UNSIGNED_16

Index: 23707

d

= 5C9B

h

Display of the 16-bit output values of the CAN interface

System bus "CAN on board"

Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Bit 0 Bit0
Bit 1 Bit1
Bit 2 Bit2
Bit 3 Bit3
Bit 4 Bit4
Bit 5 Bit5
Bit 6 Bit6
Bit 7 Bit7
Bit 8 Bit8
Bit 9 Bit9

Bit 10 Bit10
Bit 11 Bit11
Bit 12 Bit12
Bit 13 Bit13
Bit 14 Bit14
Bit 15 Bit15

Subcodes

Info

C00868/1

LP_CanOut1

: wOut1

C00868/2

LP_CanOut1

: wOut2

C00868/3

LP_CanOut1

: wOut3

C00868/4

LP_CanOut1

: wOut4

C00868/5

LP_CanOut2

: wOut1

C00868/6

LP_CanOut2

: wOut2

C00868/7

LP_CanOut2

: wOut3

C00868/8

LP_CanOut2

: wOut4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00909 | Speed limitation

Data type: INTEGER_16

Index: 23666

d

= 5C72

h

Maximum positive/negative speed for all operating modes
Setting range

(min. value | unit | max. value)

0.0

%

175.0

Subcodes

Lenze setting

Info

C00909/1

120.0 %

Max. pos. speed

C00909/2

120.0 %

Max. neg. speed

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100