2 deactivate motor potentiometer, Deactivate motor potentiometer, 11 function library – Lenze 8400 BaseLine C User Manual
Page 308
11
Function library
11.1
L_MPot_1
308
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.1.2
Deactivate motor potentiometer
When the motor potentiometer is deactivated by setting bInAct to TRUE the nOut_a output signal
responds according to the function selected in
[11-2] Example: Deactivation of the motor potentiometer if
804
= "1: Deceleration to 0"
When the motor potentiometer is deactivated, nOut_a is reduced to 0 % with the deceleration time wTif.
If it is activated again, nOut_a is increased again to nLowLimit with the acceleration time wTir.
nOut_a
t
t
TRUE
FALSE
bUp
t
TRUE
FALSE
bDown
nHighLimit
nLowLimit
0
wTir
wTif
wTir
t
TRUE
FALSE
bInAct
wTif
wTif
0
1