I-1018, I-1200, 9system bus "can on board – Lenze 8400 BaseLine C User Manual

Page 218

Advertising
background image

Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05

218

9

System bus "CAN on board"

9.9

Implemented CANopen objects | I-1018

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

I-1018

I-1200

Identifiers for SDO server channel 1 (basic SDO channel).

• According to DS301 V4.02, the basic SDO channel can neither be changed nor deactivated.

[9-13] Data telegram assignment

Index:

I-1018

Name:

Identity object

Subindex

Default setting

Display range (min. value | unit | max. value)

Access

Data type

0: Highest subindex supported

see below

0

4294967295 ro

U32

1: Vendor ID
2: Product code
3: Revision number
4: Serial number

Subindex

Meaning

1

Manufacturer's identification number

• The identification number allocated to Lenze by the organisation "CAN in Auto-

mation e. V." is "0x0000003B".

2

Product code

0x84001 8400 BaseLine C
0x84002 8400 StateLine C
0x84003 8400 HighLine C
0x84004 8400 TopLine C

3

Main and subversion of firmware

4

Serial number

Index:

I-1200

Name:

SDO1 server parameter

Subindex

Default setting

Display range (min. value | unit | max. value)

Access

Data type

0: Highest subindex supported

2

2

2 ro

U8

1: COB-ID client -> server (rx)

node ID + 0x600

0

4294967295 ro

U32

2: COB-ID server -> client (tx)

node ID + 0x580

0

4294967295 ro

U32

Subindex

Meaning

1

Specification of receive identifier

• For SDO server channel 1: node address (C350) + 0x580

2

Specification of send identifier

• For SDO server channel 1: Node address (C350) + 0x580

8th byte

7th byte

6th byte

5th byte

Data 4

Data 3

Data 2

Data 1

Bit 31

Bit 30

Bit 29 ... bit 11

Bit 10 ... bit 0

0

0

Extended identifier*

11-bit identifier

* The extended identifier is not supported. Bit 11 ... bit 29 must be set to "0".

Advertising