C00242 | l_pctrl_1: operating mode, C00243 | l_pctrl_1: acceleration time influence, C00244 | l_pctrl_1: deceleration time influence – Lenze 8400 BaseLine C User Manual

Page 266: C00245 | l_pctrl_1: pid output value, C242, C243, C244, C245, 10 parameter reference

Advertising
background image

Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05

266

10

Parameter reference

10.2

Parameter list | C00242

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00242

C00243

C00244

C00245

C00308

Parameter | Name:

C00242 | L_PCTRL_1: Operating mode

Data type: UNSIGNED_8

Index: 24333

d

= 5F0D

h

FB

L_PCTRL_1

: Selection of the operating mode

• Depending on the selection, the blue switches in the displayed signal flow are set accordingly in the Engineer on

the Application parameter tab in the OverviewSignal flowProcess controller dialog level.

Selection list

(Lenze setting printed in bold)

Info

0 Off

The input setpoint nNSet_a is output without any chan-

ges at the output nOut_a.

1 Additive + feedforward control

nNSet_a and nAct_a are used as PID input values. The ar-

riving nNSet_a is additively linked to the value output by

the PID element.

2 PID as setpoint generator.

nSet_a and nAct_a are used as PID input values. The in-

put nNSet_a is not considered.

3 PID setpoint from L_NSet_1

nNSet_a and nAct_a are used as PID input values. The in-

put nSet_a is not considered.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00243 | L_PCTRL_1: Acceleration time influence

Data type: UNSIGNED_32

Index: 24332

d

= 5F0C

h

FB

L_PCTRL_1

: Acceleration time for showing the PID output value

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

s

999.9 5.0 s

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C00244 | L_PCTRL_1: Deceleration time influence

Data type: UNSIGNED_32

Index: 24331

d

= 5F0B

h

FB

L_PCTRL_1

: Deceleration time for masking out the PID output value

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

s

999.9 5.0 s

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C00245 | L_PCTRL_1: PID output value

Data type: INTEGER_16

Index: 24330

d

= 5F0A

h

FB

L_PCTRL_1

: Display of the output value of the PID process controller

Display range

(min. value | unit | max. value)

-199.9

%

199.9

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00308 | Activation of internal features

Data type: UNSIGNED_16

Index: 24267

d

= 5ECB

h

This code is for device-internal use only and must not be written to by the user!