10.2

Parameter list | C00359

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00359

C00360

Parameter | Name:

C00359 | CAN status

Data type: UNSIGNED_8

Index: 24216

d

= 5E98

h

System bus "CAN on board"

Selection list

(read only)

0 Operational
1 Pre-Operat.
2 Reserved
3 Reserved
4 BootUp
5 Stopped
6 Reserved
7 Reset

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00360 | CAN telegram counter

Data type: UNSIGNED_16

Index: 24215

d

= 5E97

h

System bus "CAN on board"

Display range

(min. value | unit | max. value)

0

65535

Subcodes

Info

C00360/1

All PDOs/SDOs transmitted

C00360/2

All PDOs/SDOs received

C00360/3

CAN1_OUT telegram counter

C00360/4

CAN2_OUT telegram counter

C00360/5

Reserved

C00360/6

SDO1 OUT telegram counter

C00360/7

SDO2 OUT telegram counter

C00360/8

CAN1_IN telegram counter

C00360/9

CAN2_IN telegram counter

C00360/10

Reserved

C00360/11

SDO1 IN telegram counter

C00360/12

SDO2 IN telegram counter

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1