1 main setpoint path, 2 jog setpoints, Main setpoint path – Lenze 8400 BaseLine C User Manual

Page 310: Jog setpoints, 11 function library

Advertising
background image

11

Function library

11.2

L_NSet_1

310

Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Parameter

11.2.1

Main setpoint path

• The signals in the main setpoint path are limited to a value range of ±32767.
• The signal at nNSet_a is first led via the JOG selection function.
• A selected JOG value switches the nNSet_a input inactive. Then, the subsequent signal conditio-

ning operates with the JOG value.

11.2.2

JOG setpoints

In addition to the direct main setpoint selection, via the input nNSet_a JOG setpoints can be set un-

der

C039/1...3

.

• The JOG setpoints are binary-coded and can be called using the bJog1 and bJog8 selection in-

puts:

• The number of selection inputs to be assigned depends on the number of JOG setpoints re-

quired.

Parameter

Possible settings

Info

C012

0.0

s

999.9 Acceleration time T

ir

for the main set-

point

• Lenze setting: 2.0 s

C013

0.000

s

999.9 Deceleration time T

if

for the main

setpoint

• Lenze setting: 2.0 s

C039/1

-199.9

%

199.9 Fixed setpoint 1 (JOG setpoint 1)

• Lenze setting: 40.0 %

C039/2

-199.9

%

199.9 Fixed setpoint 2 (JOG setpoint 2)

• Lenze setting: 60.0 %

C039/3

-199.9

%

199.9 Fixed setpoint 3 (JOG setpoint 3)

• Lenze setting: 80.0 %

C134

Activates ramp rounding with PT1

behaviour for the main setpoint

• The corresponding S-ramp time

must be set in

C182

.

• Lenze setting: 0 (deactivated)

0 Off
1 PT1 behaviour

C182

0.01

s

50.00 S-ramp time PT1

• Lenze setting: 20.00 s

Selection inputs

Used main setpoint

bJog2

bJog1

FALSE

FALSE

nNSet_a

FALSE

TRUE

C039/1

TRUE

FALSE

C039/2

TRUE

TRUE

C039/3