C00355

C00356

C00357

Parameter | Name:

C00355 | Active COBID

Data type: UNSIGNED_16

Index: 24220

d

= 5E9C

h

Display of the COBID of the PDOs that is active in the CAN stack

System bus "CAN on board"

Display range

(min. value | unit | max. value)

0

2047

Subcodes

Info

C00355/1

Active COBID CAN1_IN

C00355/2

Active COBID CAN1_OUT

C00355/3

Active COBID CAN2_IN

C00355/4

Active COBID CAN2_OUT

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00356 | CAN time settings

Data type: UNSIGNED_16

Index: 24219

d

= 5E9B

h

Different time settings for the CAN interface

System bus "CAN on board"

Setting range

(min. value | unit | max. value)

0

ms

65000

Subcodes

Lenze setting

Info

C00356/1

3000 ms

CAN delay during status change from "Boot-up" to "Ope-

rational"

C00356/2

0 ms

CAN2_OUT cycle time

C00356/3

0 ms

CAN3_OUT cycle time

C00356/4

0 ms

CANx_OUT time "Operational" to "First transmission"

C00356/5

0 ms

CAN1_OUT cycle time

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00357 | CAN monitoring times

Data type: UNSIGNED_16

Index: 24218

d

= 5E9A

h

Mapping of the RPDO event time (see DS301 V4.02)

• If a non-zero value is entered, the RPDO is expected after the time set has elapsed.

• If the RPDO is not received within the expected time, the response set in

C00593/1...2

is effected.

System bus "CAN on board"

Setting range

(min. value | unit | max. value)

0

ms

65000

Subcodes

Lenze setting

Info

C00357/1

3000 ms

CAN1_IN monitoring time

C00357/2

3000 ms

CAN2_IN monitoring time

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT