1 identifiers of the parameter data objects, 2 user data, Identifiers of the parameter data objects – Lenze 8400 BaseLine C User Manual

Page 195: User data, 9system bus "can on board

Advertising
background image

Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05

195

9

System bus "CAN on board"

9.7

Parameter data transfer

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.7.1

Identifiers of the parameter data objects

In the Lenze setting, the basic identifiers of the SDOs are preset according to the "Predefined Con-

nection Set".
The identifiers of the parameter data objects SDO1 and SDO2 result from the basic identifier and

the node address set under code

C350

:

Identifier = basic identifier + node address

9.7.2

User data

Structure of the user data of the parameter data telegram

The following subchapters provide detailed information on user data.

Object

Direction

Lenze-Base-ID

CANopen-Base-ID

from device

to device

dec

hex

dec

hex

SDO1

(Parameter data channel 1)

TSDO1

1408

580

1408

580

RSDO1

1536

600

1536

600

SDO2

(Parameter data channel 2)

TSDO2

1472

5C0

1472

5C0

RSDO2

1600

640

1600

640

Heartbeat

1792

700

1792

700

Boot-up

1792

700

1792

700

1st byte

2nd byte 3rd byte

4th byte

5th byte

6th byte

7th byte

8th byte

Command

Index

Subindex

Data 1

Data 2

Data 3

Data 4

Low byte High byte

Low word

High word

Low byte

High byte

Low byte

High byte

Note!

The user data are presented in the Motorola format.

Parameter data telegram examples

( 201)