7drive application – Lenze 8400 BaseLine C User Manual

Page 138

Advertising
background image

7

Drive application

7.3

Setting parameters (short overview)

138

Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Output words

Name

Assignment

Word 1 DriveControlStatus

Status word

• For bit assignment, see table below.

Word 2 MotorSpeedAct

Actual speed value

• Scaling: 16384 ≡ 100 % reference speed (

C011

)

Word 3 MotorSpeedSet

Resulting overall setpoint

• Scaling: 16384 ≡ 100 % reference speed (

C011

)

Word 4 -

Not preconfigured

Status word

Name

Status

Bit 0 FreeStatusBit0

Free status bit 0 (configurable in

C621/7

)

Not assigned in Lenze setting.

Bit 1 PowerDisabled

1 ≡ Inverter control inhibited (pulse inhibit is active)

Bit 2 FreeStatusBit2

Free status bit 2 (configurable in

C621/8

)

In Lenze setting pre-assigned with LA_NCtrl_bImaxActive signal:

1 ≡ The current setpoint is internally limited (the controller ope-

rates at the maximum current limit)

Bit 3 FreeStatusBit3

Free status bit 3 (configurable in

C621/9

)

In the Lenze setting pre-assigned with

LA_NCtrl_bSpeedSetReached signal:

1 ≡ Speed setpoint reached

Bit 4 FreeStatusBit4

Free status bit 4 (configurable in

C621/10

)

In the Lenze setting pre-assigned with LA_NCtrl_bSpeedActEqSet

signal:

1 ≡ Actual speed value has reached the setpoint within one hys-

teresis band

Bit 5 FreeStatusBit5

Free status bit 5 (configurable in

C621/11

)

In the Lenze setting pre-assigned with LA_NCtrl_bNActCompare

signal:

• In case of "open loop" operation:

1 ≡ speed setpoint < comparison value (

C024

)

• In case of "open loop" operation

1 ≡ actual speed value < comparison value (

C024

)

Bit 6 ActSpeedIsZero

1 ≡ current speed is 0

Bit 7 ControllerInhibit

1 ≡ Controller inhibited (controller inhibit is active)

Bit 8 StatusCodeBit0

Bit coded display of the active device state

Device states

(see table

[4-1]

)

Bit 9 StatusCodeBit1

Bit 10 StatusCodeBit2
Bit 11 StatusCodeBit3
Bit 12 Warning

1 ≡ A warning exists.

Bit 13 Trouble

1 ≡ Controller is in the "

Trouble

" device state

• E.g. if an overvoltage has occurred.

Bit 14 FreeStatusBit14

Free status bit 14 (configurable in

C621/12

)

In the Lenze setting pre-assigned with LA_NCtrl_bSpeedCcw sig-

nal:

0 ≡ Clockwise direction of rotation (Cw), 1 ≡ Counter-clockwise

direction of rotation (Ccw)

Bit 15 FreeStatusBit15

Free status bit 15 (configurable in

C621/13

)

In Lenze setting pre-assigned with LA_NCtrl_bDriveReady signal:

1 ≡ Drive controller is ready for operation

Advertising