C00136 | communication control words, C136/2, 10 parameter reference – Lenze 8400 BaseLine C User Manual

Page 254

Advertising
background image

Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05

254

10

Parameter reference

10.2

Parameter list | C00136

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00136

Parameter | Name:

C00136 | Communication control words

Data type: UNSIGNED_16

Index: 24439

d

= 5F77

h

Control words of the communication interfaces
Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Bit 0 SwitchOn
Bit 1 IMP
Bit 2 SetQuickStop
Bit 3 EnableOperation
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 ResetFault
Bit 8 SetHalt
Bit 9 reserved_1

Bit 10 reserved_2
Bit 11 LenzeSpecific_1
Bit 12 LenzeSpecific_2
Bit 13 LenzeSpecific_3
Bit 14 SetFail
Bit 15 LenzeSpecific_4

Subcodes

Info

C00136/1

Reserved

C00136/2

CAN control word

• Control word of the communication interface CAN

(CAN on board)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Advertising