Configuration parameters for analog setpoints:

Display parameter

bRLQCcw

(

C701/18

)

0: Not connected

Activate counter-clockwise rotation (fail-safe)

bSetSpeedCcw

(

C701/5

)

14: DigIn_bIn4

(DI4)

Change of direction of rotation

bJogSpeed1

(

C701/6

)

11: DigIn_bIn1

(DI1)

Selection of fixed setpoints (JOG setpoints)

bJogSpeed2

(

C701/7

)

12: DigIn_bIn2

(DI2)

bPIDEnableInfluenceRamp

(

C701/15

)

1: C_bTrue

L_PCTRL_1

: Activate ramp for influencing factor

bPIDOff

(

C701/16

)

0: Not connected

L_PCTRL_1

: Switch off I component

bCInh

(

C701/1

)

1: C_bTrue

Enable/Inhibit controller

bFailReset

(

C701/2

)

15: DigIn_CInh

(RFR)

Reset of error message

bSetQuickstop

(

C701/3

)

0: Not connected

Enable quick stop (QSP)

bSetDCBrake

(

C701/3

)

13: DigIn_bIn3

(DI3)

Manual DC-injection braking (DCB)

Parameter

Selection of signal source

(Lenze setting)

for setpoint selection:

nMainSetValue_a

(

C700/1

)

10: AIn1_Out

(Analog input 1)

Main setpoint

• 100 % ≡ reference speed (

C011

)

nPIDSetValue_a

(

C700/9

)

0: Not connected

L_PCTRL_1

: Sensor setpoint or process setpoint for ope-

rating mode 2

nPIDVpAdapt_a

(

C700/6

)

1: C_nPos100_a

(100%)

L_PCTRL_1

: Adaptation of the gain Vp set in

C222

in per-

cent

nPIDActValue_a

(

C700/7

)

0: Not connected

L_PCTRL_1

: Actual speed value or actual sensor value

(actual process value)

nPIDInfluence_a

(

C700/8

)

1: C_nPos100_a

(100%)

L_PCTRL_1

: Limitation of the influencing factor in per-

cent

Parameter

Info

nIn_a

(

C830/11

)

Input value of motor potentiometer

nNSet_a

(

C830/1

)

Input value of setpoint generator

nOut_a

(

C830/2

)

Output value of setpoint generator

nSpeedSetValue_a

(

C830/2

)

Speed setpoint for motor control

nSet_a

(

C830/8

)

Sensor setpoint or process setpoint for operating mode 2

nAdapt_a

(

C830/7

)

Adaptation of the gain Vp set in

C222

in percent

nAct_a

(

C830/6

)

Speed or actual sensor value (actual process value)

Parameter