C00347 | can status heartbeat producer, C00350 | can node address, C00351 | can baud rate – Lenze 8400 BaseLine C User Manual

Page 269: Ayed in, C347/1, Ustable per code, C350, C351, A code, Code

Advertising
background image

10

Parameter reference

10.2

Parameter list | C00347

269

Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00347

C00350

C00351

Parameter | Name:

C00347 | CAN status HeartBeat producer

Data type: UNSIGNED_8

Index: 24228

d

= 5EA4

h

System bus "CAN on board": Heartbeat protocol

Selection list

(read only)

0 Boot-up
4 Stopped
5 Operational

127 Pre-Operational
250 Failed
255 NoResponse

Subcodes

Info

C00347/1

Status node 1

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00350 | CAN node address

Data type: UNSIGNED_8

Index: 24225

d

= 5EA1

h

Setting of the node address via parameters

• The node address can only be parameterised if the node address "0" is set via the DIP switches.

• A change of the node address will only become effective after a CAN reset node.

System bus "CAN on board"

Setting range

(min. value | unit | max. value)

Lenze setting

1

63 1

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00351 | CAN baud rate

Data type: UNSIGNED_8

Index: 24224

d

= 5EA0

h

Setting of the baud rate via parameters

• The baud rate can only be parameterised if the baud rate "0" is set via the DIP switches.

• A change of the baud rate will only become effective after a CAN reset node.

System bus "CAN on board"

Selection list

(Lenze setting printed in bold)

0 500 kbps
1 250 kbps
2 125 kbps
3 50 kbps
4 1000 kbps
5 20 kbps

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1