57

4

Device control (DCTRL)

4.2

Device states

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2.4

ReadyToSwitchON

In the "ReadyToSwitchOn" device state

• is the controller after the initialisation has been completed successfully.
• is the controller even after cancelling "

Trouble

", "

Fault

" or "

SafeTorqueOff

".

• I/O signalare evaluated.
• the monitoring modes are active.
• the controller can be parameterised.
• the application is basically executable.
• prevents in the Lenze setting the auto-start option "Inhibit at power-on" activated in

C142

from

changing to the "

SwitchedON

" state.

LED DRIVE READY

LED DRIVE ERROR

Display in

C137

Display in status word 1 (

C150

)

Bit 11

Bit 10

Bit 9

Bit 8

OFF

ReadyToSwitchON

0

0

1

1

Danger!

If the "Inhibit at power-on" auto-start option has been deactivated in

C142

the "Ready-

ToSwitchOn" state directly switches to the "

SwitchedON

" state.

"Inhibit at power-on" auto-start option