Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05

35

3

Commissioning

3.4

Commissioning with the »Engineer«

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Parameterise application
On the right of the Application parameters tab, the parameters of the application are arranged:

1. Select the required control mode in the Control mode (

C007

) list field.

• The corresponding wiring diagram is displayed in a pop-up window if you click the

button

right to the list field.

• For a detailed description, see chapter entitled "

Terminal assignment of the control modes

".

( 139)

2. Optional: Use process controller.

• For this purpose select the required operating mode in the L_PCTRL_1: Operating mode

(

C242

) list field.

• For a detailed description see the function block

L_PCTRL_1

.

( 312)

• The parameterisation dialog of the process controller can be accessed via the Process

controller button.

3. Optional: Use motor potentiometer.

• For this purpose, select "1: On" in the L_MPot_1: Use (

C806

) list field.

• For a detailed description see the function block

L_MPot_1

.

( 305)

• The parameterisation dialog of the process controller can be accessed via the Motor

potentiometer button.