Behavior – GAI-Tronics TMA Version 7.5.0 Telephone Management Application (TMA) User Guide (Ver. 7.5.0 and newer) User Manual

Page 32

Advertising
background image

Pub. 42004-479B

Telephone Management Application (TMA) User Guide

Page 29 of 128

e:\standard ioms - current release\42004 instr. manuals\42004-479b.doc
03/14

Behavior

The Behavior Properties Form for a Type A Hands-free phone record is shown below followed by an
explanation of each parameter.

Table 6. Behavior Parameters and Functions

Parameter Function

Timeout Limit
(hh:mm:ss)

The Timeout Limit sets the duration of a user call at the telephone. At the end of
the timeout period, the telephone automatically terminates the call.

This parameter displays two fields with entries made only in the first (number)
field. Entries in the number field are in 0.5-second increments. The second field
displaying “hh:mm:ss” cannot be changed.
Example: A numerical value of 1200 = 10 minutes (as shown above). The
minimum call duration is 1 minute (a numerical value of 120). The maximum
duration is 04:33:04.

Primary Dial Tone
Delay

Primary Dial Tone Delay controls the time limit the telephone uses to detect dial
tone. The recommended setting is 3–5 seconds.
N

OTE

: If dial tone is not detected within the specified time, dialing will proceed.

Secondary Dial
Tone Delay

Secondary Dial Tone Delay controls the time limit the telephone uses to detect dial
tone after a digit is entered to access an outside line. The recommended setting is
2–4 seconds.
N

OTE

: If dial tone is not detected within the specified time, dialing will proceed.

Advertising
This manual is related to the following products: